Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Arrhythm ; 40(2): 349-355, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38586843

RESUMEN

Objective: Postoperative pain is a major issue with subcutaneous implantable cardioverter defibrillators (S-ICD). In 2020, we introduced intravenous patient-controlled analgesia (IV-PCA) in addition to the conventional, request-based analgesia for postoperative pain control in S-ICD. To determine the effect and safety, we quantitatively assessed the effect of IV-PCA after S-ICD surgery over conventional methods. Methods: During the study period, a total of 113 consecutive patients (age, 50.1 ± 15.5 years: males, 101) underwent a de novo S-ICD implantation under general anesthesia. While the postoperative pain was addressed with either request-based analgesia (by nonsteroid anti-inflammatory drugs, N = 68, dubbed as "PCA absent") or fentanyl-based IV-PCA in addition to the standard care (N = 45, dubbed as "PCA present"). The degree of postoperative pain from immediately after surgery to 1 week were retrospectively investigated by the numerical rating scale (NRS) divided into four groups at rest and during activity (0: no pain, 1-3: mild pain, 4-6: moderate pain, 7-10: severe pain). Results: Although IV-PCA was removed on Day 1, it was associated with continued better pain control compared to PCA absent group. At rest, the proportion of patients expressing pain (mild or more) was significantly lower in the PCA present group from Day 0 to Day 4. In contrast to at rest, a better pain control continued through the entire study period of 7 days. No serious adverse events were observed. A few patients experienced nausea in both groups and the inter-group difference was not found significant. Conclusion: IV-PCA suppresses postoperative pain in S-ICD without major safety concerns.

2.
J Interv Card Electrophysiol ; 67(1): 147-155, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37311981

RESUMEN

BACKGROUND: The lesion index (LSI) helps predict the lesion size and is widely used in ablation of various types of arrhythmias. However, the influence of the ablation settings on the lesion formation and incidence of steam pops under the same LSI value remains unclear. METHODS: Using a contact force (CF) sensing catheter (TactiCath™) in an ex vivo swine left ventricle model, RF lesions were created with a combination of various power steps (30 W, 40 W, 50 W) and CFs (10 g, 20 g, 30 g, 40 g, 50 g) under the same LSI values (5.2 and 7.0). The correlation between the lesion formation and ablation parameters was evaluated. RESULTS: Ninety RF lesions were created under a target LSI value of 5.2, and eighty-four were developed under a target LSI value of 7.0. In the LSI 5.2 group, the resultant lesion size widely varied according to the ablation power, and a multiple regression analysis indicated that the ablation energy delivered was the best predictor of the lesion formation. To create a lesion depth > 4 mm, an ablation energy of 393 J is the best cutoff value, suggesting a possibility that ablation energy may be used as a supplemental marker that better monitors the progress of the lesion formation in an LSI 5.2 ablation. In contrast, such inconsistency was not obvious in the LSI 7.0 group. Compared with 30 W, the 50-W ablation exhibited a higher incidence of steam pops in both the LSI 5.2 and 7.0 groups. CONCLUSIONS: The LSI-lesion size relationship was not necessarily consistent, especially for an LSI of 5.2. To avoid any unintentional, weak ablation, the ablation energy may be a useful supportive parameter (393 J as a cutoff value for a 4-mm depth) during ablation with an LSI around 5.2. Thanks to a prolonged ablation time, the LSI-lesion size relationship is consistent for an LSI of 7.0. However, it is accompanied by a high incidence of steam pops. Care should be given to the ablation settings even when the same LSI value is used.


Asunto(s)
Ablación por Catéter , Porcinos , Animales , Vapor , Ventrículos Cardíacos/cirugía , Arritmias Cardíacas/cirugía
3.
Radiat Prot Dosimetry ; 200(2): 149-154, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-37987214

RESUMEN

The aim of this study was to estimate the administered dosage of 81mKr noble gas as calculated by the radioactivity of 81Rb-rubidium hydroxide (81RbOH). The administered dosage was regarded as the total amount of 81mKr noble gas. The radioactivity of 81mKr was calculated using the radioactivity of 81RbOH at the examination, the beginning of inhalation, the inhalation duration and the attenuation volume from the generator to the patient for 81mKr noble gas. In addition, we created an Internet survey and asked National University Hospital in Japan to respond to questions regarding the parameters of concern. Survey responses were provided by 38 hospitals (response rate was 90.5%). Twenty-seven hospitals (64.3%) examined lung ventilation scintigraphy using 81mKr noble gas. The mean administered dosage and the effective dose of lung ventilation scintigraphy using 81mKr noble gas were 35.8 ± 22.1 GBq and 0.97 ± 0.60 mSv, respectively.


Asunto(s)
Pulmón , Rubidio , Humanos , Cintigrafía , Pulmón/diagnóstico por imagen , Japón
4.
Sci Rep ; 13(1): 18875, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37914708

RESUMEN

Average beat interval (BI) and beat interval variability (BIV) are primarily determined by mutual entrainment between the autonomic-nervous system (ANS) and intrinsic mechanisms that govern sinoatrial node (SAN) cell function. While basal heart rate is not affected by age in humans, age-dependent reductions in intrinsic heart rate have been documented even in so-called healthy individuals. The relative contributions of the ANS and intrinsic mechanisms to age-dependent deterioration of SAN function in humans are not clear. We recorded ECG on patients (n = 16 < 21 years and n = 23 41-78 years) in the basal state and after ANS blockade (propranolol and atropine) in the presence of propofol and dexmedetomidine anesthesia. Average BI and BIV were analyzed. A set of BIV features were tested to designated the "signatures" of the ANS and intrinsic mechanisms and also the anesthesia "signature". In young patients, the intrinsic mechanisms and ANS mainly contributed to long- and short-term BIV, respectively. In adults, both ANS and intrinsic mechanisms contributed to short-term BIV, while the latter also contributed to long-term BIV. Furthermore, anesthesia affected ANS function in young patients and both mechanisms in adult. The work also showed that intrinsic mechanism features can be calculated from BIs, without intervention.


Asunto(s)
Atropina , Nodo Sinoatrial , Adulto , Humanos , Propranolol , Frecuencia Cardíaca/fisiología , Sistema Nervioso Autónomo/fisiología , Electrocardiografía
5.
J Arrhythm ; 39(2): 166-174, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37021033

RESUMEN

Background: Recently, a novel contact force (CF) sensing catheter with mesh-shaped irrigation tip (TactiFlex SE, Abbott) was invented and is expected to be useful for safe and effective radiofrequency ablation. However, this catheter's detailed characteristics of the lesion formation are unknown. Methods: With an in vitro model, TactiFlex SE and its predecessor, FlexAbility SE, were used. A cross-sectional analysis of 60 s lesions (combination of various energy power settings [30, 40, and 50 W], and CFs [10, 30, and 50 g]) and longitudinal analysis (combination of various powers [40 or 50 W], CFs [10, 30, and 50 g] and ablation times [10, 20, 30, 40, 50, and 60 s]) of both catheters were analyzed and compared. Results: One hundred eighty RF lesions were created in protocol 1 and 300 in protocol 2. The lesion formation, impedance changes, and steam pops characteristics were similar between the two catheters. Higher CFs were related to higher incidences of steam pops. A nonlinear, time-dependent increase in the lesion depth and diameter was observed for all power and CF settings, and linear, positive correlations between the RF delivery time and lesion volume were observed for all power settings. Compared with 40 W, a 50 W ablation created greater lesions. Longer durations with higher CF settings had a higher steam pop incidence. Conclusions: The lesion formation and incidence of steam pops with TactiFlex SE and FlexAbility SE were similar. A 40 or 50 W ablation with careful CF control not to exceed 30 g in addition to monitoring impedance drops was required to safely create transmural lesions.

6.
J Cardiol ; 82(1): 76-83, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36935004

RESUMEN

BACKGROUND: A novel Diamond Temp™ (DT; Medtronic, Minneapolis, MN, USA) catheter has enabled performing a surface temperature-controlled ablation. The chemical vapor deposition diamond of the ablation catheter acts as a thermal radiator and is useful for effective cooling of the ablation catheter tip. However, a detailed analysis of the lesion formation with this catheter remains unknown. METHODS: DT catheters were used in an excised swine heart experimental model. A cross-sectional analysis of 60-s lesions [a combination of various energy power settings (30, 40, and 50 W), and various contact forces (CF) (10, 30, and 50 g)] and a longitudinal analysis [a combination of various powers (40 W or 50 W), various CFs (10, 30, and 50 g), and various ablation times (5 s, 10 s, 15 s, 20 s, 25 s, 30 s, and 60 s)] of the DT catheter were analyzed. RESULTS: The maximum lesion depth, maximum diameter, and lesion volume with a 10 g ablation were significantly lower than those with a 30 g or 50 g ablation. There were no significant differences in the lesion formation between the 30 g ablation and 50 g ablation under each radiofrequency (RF) power setting. The impedance drops with steam pops were significantly greater than those without steam pops (pop (+) vs. pop (-), 26.2 ±â€¯6.6 Ohm vs. 18.4 ±â€¯7.1 Ohm, p = 0.0001). A non-linear, time-dependent increase in the lesion depth and diameter was observed for all power and CF settings. Comparing the lesion depth and diameter between 40 W and 50 W under the same CF setting and same ablation time, most of the settings had no significant difference. CONCLUSION: Ablation lesions created with the DT catheter were similar to other catheters. Similar ablation lesions were created with the 40 W or 50 W ablation under the same CF setting and same ablation time. Regardless of the ablation power, monitoring the general impedance during the RF application was indispensable for a safe procedure.


Asunto(s)
Ablación por Catéter , Vapor , Animales , Porcinos , Estudios Transversales , Catéteres , Corazón , Ventrículos Cardíacos/patología , Ablación por Catéter/métodos , Diseño de Equipo
7.
J Arrhythm ; 38(6): 1080-1087, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36524038

RESUMEN

Background: The local impedance (LI) is an emerging technology that monitors tissue-catheter coupling during radiofrequency (RF) ablation. The relationships between the LI, RF delivery time, and lesion formation remain unclear. Methods: Using an LI-enabled RF catheter in an ex vivo experimental model, RF lesions were created combined with various steps in the power (40 and 50 W), CF (10 g, 30 g, and 50 g), and time (10s, 20s, 30s, 40s, 50s, and 60s at 40 W and 5 s, 10s, 20s, 30s, 40s, 50s, and 60s at 50 W). The correlations between the LI drop, lesion size, and RF delivery time were evaluated. The rate of change in the time-dependent gain in the LI, depth, and diameter and the time to reach 90% decay of the peak dY/dT (time to 90% decay) were assessed. Results: The correlation between the LI drop and ablation time revealed non-linear changes. The time to a 90% decay in the LI drop differed depending on the RF ablation setting and was always shorter with the 50 W setting than 40 W setting. The LI drop always correlated with the lesion formation under all ablation power settings. Deeper or wider lesions were predominantly created within the time to 90% decay of the LI drop. Conclusion: The LI drop was useful for predicting lesion sizes. Deeper or wider lesions cannot be obtained with a longer ablation than the 90% decay time of the LI drop. A shorter ablation than the 90% decay time of the LI drop would be preferable for an effective ablation.

8.
Postepy Kardiol Interwencyjnej ; 17(2): 163-169, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34400918

RESUMEN

INTRODUCTION: In percutaneous coronary intervention (PCI) to atherosclerotic lesions in the right coronary artery (RCA), coronary artery dissection in the ostium of the RCA is a rare but fatal complication. Stent implantation to the ostium of RCA may be selected for the prevention of aorto-ostial dissection. AIM: To find factors associated with aorto-ostial stent coverage to mild to moderate ostial stenosis during the treatment of severely narrowed non-ostial RCA lesions. MATERIAL AND METHODS: The primary interest was to find factors associated with ostial stent coverage using multivariate regression analysis. We included 236 patients who underwent intravascular ultrasound (IVUS)-guided PCI to severely narrowed RCA lesions with mild to moderate ostial stenosis, and divided those into the ostial-coverage group (n = 52) and the non-coverage group (n = 184). RESULTS: The prevalence of continuous ostial plaque detected by intravascular ultrasound (IVUS) was significantly greater in the ostial-coverage group (84.6%) than in the non-coverage group (52.9%) (p < 0.001). Multivariate logistic regression analysis revealed that continuous ostial plaque detected by IVUS (OR = 5.398, 95% CI: 2.322-12.553, p < 0.001) was significantly associated with ostial stent coverage after controlling confounding factors. Ischaemia-driven target vessel revascularization was less frequently observed in the ostial-coverage group than in the non-coverage group, without reaching statistical significance (p = 0.069). CONCLUSIONS: Continuous ostial plaque detected by IVUS was significantly associated with ostial stent coverage to the mild to moderate stenosis when PCI to non-ostial, severely narrowed RCA lesions was performed. The use of IVUS may enhance the safety but may increase the total stent length in PCI to RCA.

9.
Appl Radiat Isot ; 176: 109856, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34273618

RESUMEN

We have developed a new real-time neutron detector, which is able to measure a direct neutron beam of boron neutron capture therapy. The detector consists of both a 40-µm-thick pn diode and around 0.09-µm-thick LiF neutron converter. Experimental results indicate that this neutron detector can measure neutron flux up to 1 × 109 (cm-2 s-1), separately from gamma rays around 500 mGy/h. The measured depth distribution of neutron flux in an acrylic block is in agreement with the activation results of gold.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Neutrones , Silicio/química , Rayos gamma
10.
Int Heart J ; 60(1): 215-219, 2019 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-30464129

RESUMEN

Takotsubo cardiomyopathy is a common disease, but Takotsubo cardiomyopathy complicated by ventricular septal perforation is very rare. We describe the case of a 92-year-old male who had Takotsubo cardiomyopathy complicated by ventricular septal perforation. We treated the patient medically without surgical or catheter interventions. In three weeks, his abnormal wall motion recovered completely, whereas the ventricular septal perforation remained open. He was ambulatory, subsequently discharged, and had been uneventful for one year. In this manuscript, we discuss the importance of non-invasive management for Takotsubo cardiomyopathy complicated by ventricular septal perforation.


Asunto(s)
Tratamiento Conservador/métodos , Cardiomiopatía de Takotsubo/complicaciones , Rotura Septal Ventricular/etiología , Anciano de 80 o más Años , Ecocardiografía , Electrocardiografía , Humanos , Masculino , Cardiomiopatía de Takotsubo/fisiopatología , Cardiomiopatía de Takotsubo/terapia , Resultado del Tratamiento , Rotura Septal Ventricular/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...